Progressive International Electronics RLMVersion 1.1 / November 98 Page 1rlminstl.mnlSystem InstallationSystem WarningsSafety hazards are inherent wit
RLM Progressive International ElectronicsPage 2 Version 1.1 / November 98rlminstl.mnlSystem InstallationSystem EvaluationImportant!One of the most imp
Progressive International Electronics RLMVersion 1.1 / November 98 Page 3rlminstl.mnlSystem InstallationSystem Installation ChecklistThe line monitori
RLM Progressive International ElectronicsPage 4 Version 1.1 / November 98rlminstl.mnlSystem InstallationSystem Installation RequirementsIn preparation
Progressive International Electronics RLMVersion 1.1 / November 98 Page 5rlminstl.mnlSystem InstallationDescription of RLM ComponentsThe RLM systems a
RLM Progressive International ElectronicsPage 6 Version 1.1 / November 98rlminstl.mnlRLM Power RequirementsThe RLM must be powered from a dedicated 11
Progressive International Electronics RLMVersion 1.1 / November 98 Page 7rlminstl.mnl 3. Referring to Connector/Jumper Layout diagram on the next p
RLM Progressive International ElectronicsPage 8 Version 1.1 / November 98rlminstl.mnlDiagram: RLM (Electronic) Connector/Jumper Layout
Progressive International Electronics RLMVersion 1.1 / November 98 Page 9rlminstl.mnlDiagram: RLM (Electronic) Multi Board 485 Link
RLM Progressive International ElectronicsPage 10 Version 1.1 / November 98rlminstl.mnlDiagram: RLM (Electronic) Board 1 in RS232/RS485 Link
© Copyright 1998Progressive International Electronics
123456789101112J1J2J3J4J8J7J6J5J5J6J7J8W6W4 W5monitor monitorcomputer computerConn 1 -> 12VAC inputConn 5 -> CommunicationsRLM Electronic485 Lin
RLM Progressive International ElectronicsPage 12 Version 1.1 / November 98rlminstl.mnlTable: RLM (Electronic) Jumper SettingsJumper headers J1-J12 ar
Progressive International Electronics RLMVersion 1.1 / November 98 Page 13rlminstl.mnlRLM Power RequirementsThe RLM must be powered from a dedicated 1
RLM Progressive International ElectronicsPage 14 Version 1.1 / November 98rlminstl.mnl 3. Referring to Connector/Jumper Layout diagram on the follo
Progressive International Electronics RLMVersion 1.1 / November 98 Page 15rlminstl.mnlDiagram: RLM (Mechanical) Connector/Jumper Layout
RLM Progressive International ElectronicsPage 16 Version 1.1 / November 98rlminstl.mnlDiagram: Pulser/MR Circuit
Progressive International Electronics RLMVersion 1.1 / November 98 Page 17rlminstl.mnlSystem InstallationPump Specific InstallationRLM-G for Gilbarco
RLM Progressive International ElectronicsPage 18 Version 1.1 / November 98rlminstl.mnlLocate an unused position in the Gilbarco DBox and ensure thatth
Progressive International Electronics RLMVersion 1.1 / November 98 Page 19rlminstl.mnlTable: Gilbarco DBoxesGilbarco dispensing systems use several ty
Gilbarco Adapter — P/N 1700 12 0007D3Red LEDD4Green LEDRS422TWIJ4Current LoopTWIJ3RS422For current loop ope
iRLM Remote Line Monitor SystemINSTALLATION GUIDECONTENTSSystem Installation ... 1System Warnings ...
Progressive International Electronics RLMVersion 1.1 / November 98 Page 21rlminstl.mnlDiagram: RLM-G to Gilbarco DBox PA01330000
RLM Progressive International ElectronicsPage 22 Version 1.1 / November 98rlminstl.mnlDiagram: RLM-G to Gilbarco DBox Universal/TS1000
GilbarcoDBoxPA03060020DB9 to RJ45AdaptersGilbarco Consoleor ControllerRLM Adapter CablePIE 9000 15 0027RLM-GRLM-G to Gilbarco DBoxPA03060020 with RJ45
RLM Progressive International ElectronicsPage 24 Version 1.1 / November 98rlminstl.mnlSystem InstallationPump Specific InstallationRLM-GS for Gilbarco
Progressive International Electronics RLMVersion 1.1 / November 98 Page 25rlminstl.mnlIf the G-SITE is using the C2 style controller, both adapters wi
Gilbarco G-SITE ControllerC2 StyleRLM G-SITE Adapter CableRJ45 StylePN 9000 15 0045RJ45 to DB9 Adapter9000 16 0003RJ45 to DB25 Adapter9000 16 0002RLM-
Progressive International Electronics RLMVersion 1.1 / November 98 Page 27rlminstl.mnlDiagram: RLM-GS to Gilbarco 486 G-SITE
RLM Progressive International ElectronicsPage 28 Version 1.1 / November 98rlminstl.mnlSystem InstallationPump Specific InstallationRLM-W for Wayne/Dre
Progressive International Electronics RLMVersion 1.1 / November 98 Page 29rlminstl.mnlDiagram: RLM-W for Wayne/Dresser — Typical Installation
1 2 3 4 5 6+ -1 2 3 4 5 6+ -+-+-Wayne/Dresser DBox RLM-W Connection ExampledataindataindataoutdataoutPumpCommunicationConnectionsData Linesto Dispense
iiRLM-W for Wayne/Dresser Electronic Dispenser ... 28Diagram: RLM-W for W/D — Typical Installation ... 29Diagram: W/D DBox RLM-W Connection Ex
Progressive International Electronics RLMVersion 1.1 / November 98 Page 31rlminstl.mnlSystem InstallationPump Specific InstallationRLM-T for Tokheim E
RLM Progressive International ElectronicsPage 32 Version 1.1 / November 98rlminstl.mnlDiagram: RLM-T for Tokheim — Typical Installation
Progressive International Electronics RLMVersion 1.1 / November 98 Page 33rlminstl.mnlDiagram: RLM Tokheim Adapter Board
RLM Progressive International ElectronicsPage 34 Version 1.1 / November 98rlminstl.mnlSystem InstallationPump Specific InstallationRLM-S for Schlumber
Progressive International Electronics RLMVersion 1.1 / November 98 Page 35rlminstl.mnlDiagram: RLM-S to Schlumberger SAM — Typical Installation
RLM Progressive International ElectronicsPage 36 Version 1.1 / November 98rlminstl.mnlDiagnosticsTesting the RLM Using Tester/WinTesterShipped with ea
Progressive International Electronics RLMVersion 1.1 / November 98 Page 37rlminstl.mnl 2. Go to A:\ drive. Insert the Tester diskette and type Te
RLM Progressive International ElectronicsPage 38 Version 1.1 / November 98rlminstl.mnl 1. Go to A:\. Insert the WinTester diskette and, from the
Progressive International Electronics RLMVersion 1.1 / November 98 Page 39rlminstl.mnlDiagnosticsTroubleshooting Electronic VersionsRLM/E DiagnosticsP
RLM Progressive International ElectronicsRLM/E DiagnosticsPROBLEM RECOMMENDATIONPage 40 Version 1.1 / November 98rlminstl.mnlRLM does not capture any
iiiRLMHISTORY OF DOCUMENTATIONCHANGES & REVISIONSVersion 1.0 — April 20, 1998Version 1.1 — November 1998 (preliminary release)
Progressive International Electronics RLMVersion 1.1 / November 98 Page 41rlminstl.mnlDiagnosticsTroubleshooting Mechanical VersionsRLM/M DiagnosticsP
RLM Progressive International ElectronicsRLM/M DiagnosticsPROBLEM RECOMMENDATIONPage 42 Version 1.1 / November 98rlminstl.mnlRLM/M data does not match
Progressive International Electronics RLMVersion 1.1 / November 98 Page 43rlminstl.mnlDiagnosticsPump-Specific TroubleshootingGilbarcoPROBLEM RECOMMEN
RLM Progressive International ElectronicsPage 44 Version 1.1 / November 98rlminstl.mnlDiagnosticsPump-Specific TroubleshootingGilbarco MOC G-SITEPROBL
Progressive International Electronics RLMVersion 1.1 / November 98 Page 45rlminstl.mnlDiagnosticsPump-Specific TroubleshootingTokheimPROBLEM RECOMMEND
RLM Progressive International ElectronicsPage 46 Version 1.1 / November 98rlminstl.mnlDiagnosticsPump-Specific TroubleshootingWayne/DresserPROBLEM REC
Progressive International Electronics RLMVersion 1.1 / November 98 Page 47rlminstl.mnlDiagnosticsPump-Specific TroubleshootingSchlumbergerPROBLEM RECO
RLM Progressive International ElectronicsPage 48 Version 1.1 / November 98rlminstl.mnlDiagnosticsPump-Specific TroubleshootingMechanical DispenserPROB
Progressive International Electronics RLMVersion 1.1 / November 98 Page 49rlminstl.mnlGeneral Technical InformationThis section contains miscellaneous
RLM Progressive International ElectronicsPage 50 Version 1.1 / November 98rlminstl.mnlDiagram: RLM RS232 Cable Connector 5 Pinout
ivRLMPURPOSE OF THIS DOCUMENTThis manual contains instructions for installation of the Remote LineMonitor systems used to monitor transactions between
Progressive International Electronics RLMVersion 1.1 / November 98 Page 51rlminstl.mnlRLM General SpecsTable: RLM General SpecificationsPhysical Size
vRLMWARRANTYProgressive International Electronics, Inc. (PIE) warrants to the Purchaserof the RLM equipment manufactured by PIE against defects in mat
vi PIE’s warranty applies only if the equipment has been installedand used in accordance with PIE’s instructions. The warranty isvoid if any
viiRLMEXPLANATION OF DOCUMENT STANDARDSThe following documentation standards are applied throughout thisdocument. I Comments are noted in italics.X Va
Comentários a estes Manuais